The new step cannot be inserted up behind the stucco and house wrap because the weep screen at the bottom of the stucco is attached to the wall with nails.
Step flashing attached to roof or wall.
It is always recommended to install step flashing behind stucco dryvit wood panel lap siding vinyl siding cedar shingle siding etc.
Continuous flashing against a sidewall is one way to install a roof but it s not the correct way.
Bend it back so that it overlaps the corner flashing.
This can be under shingles or over metal roofing material.
Nail it in place with two nails one.
Riley shows his way the only way how to install step flashing.
Step flashing redirects the water back onto the shingle.
4 inches should go up the house wall and 4 inches should go on top of the porch roof shingles.
The shingle s weather exposure is 5.
However in most instances step flashing should be installed behind siding.
How to install step flashing with a wall corner step three.
Riley says most roofers use.
The flashing extends up the wall at least 4.
You have to first decide what size of flashing you will use.
Step 6 make a 10 degree bend on the shingle edge of the flashing approximately 1 2 inch from the edge.
Here s how to install it correctly.
It s crucial that step flashing be installed on all roof to wall transitions.
Then set the piece down.
While 8 inch flashing usually works well for most purposes you might want to use another size.
Step 1 choose what kind of metal flashing you need.
Riley explains its easy to do when it comes to new construction.
Step flashings on a cedar shake roof are typically installed every 10 inches.
The flashing extends onto the roof a minimum of 2 inches 4 inches is preferable in more severe climate areas.
Even if one piece of step flashing fails the flashing and shingle below it start the process over again.
The metal flashing is formed with a hook edge and cleated on 12 centers.
Failing to replace step flashings when a cedar shake roof is replaced with a composition shingle roof.
Vent flashing done right to prevent leaks back up roof vent boots with flashing counterflashing and proper shingling.
Use the metal break tool to bend the flashing lengthwise in the middle according to the angle of the roof joint.
It may seem as if a single piece of flashing would offer more protection than many pieces of step flashing.
Epdm flashing tape with a butyl adhesive backing will help.
Step 2 install base flashing.
Garage or additions that are attached to a second level area and also installed around skylights and around and up chimneys where it becomes overlapped by counter flashing.
Flashing joints are lapped 6 in the direction of water flow.
Ensure it sits flat and extends at least 8 inches above the shingles.
The new step flashing must extend up the wall a minimum of 4 and must be laced with each course of the new asphalt shingles.
This includes dormers one story attached sections of the house e g.
Hammer one nail to the.